Colocation / Housing at the InterNetX Data Center Munich
InterNetX operates its own ISO-certified data center built to Tier 3 standards in Munich, specifically tailored to the requirements of housing customers – available as individual rack units (U), a third rack, or a full lockable rack.
Benefits of Colocation / Housing with InterNetX at a Glance
- ISO-certified data center compliant with Tier 3 standards and DIN EN 50600
- GDPR-compliant
- 24/7 NOC & hands-on services bookable around the clock
- Custom requirements such as Dark Fiber Connect, in-house cabling to the carrier room, and caging (cage) available
- Goods receipt and storage of customer hardware and spare parts on site
- Separate workspace (“Unpack & Deploy Room”) outside the climate-controlled server room
- Flexible booking of individual rack units or full lockable racks
- For dedicated racks (47 U or 15 U “third rack”):
- Individually lockable and secured with a PIN code
- Biometric registration of staff for free 24/7 access without advance notice (for full racks)
- In-house cabling to the carrier room
Key Features of Housing with InterNetX
- DE-CIX-Enabled Site: Extremely low latencies to the DE-CIX peering POPs
- Cold Aisle Containment: Energy-saving, consistent cooling performance
- Double Ceiling Height: Lower cooling requirements and reduced power consumption
- Tall Racks: 47 U instead of the standard 42 U
- Lockable Racks
- 24/7 Access: Without advance notice or accompaniment when booking a full rack (following biometric registration)
- 24/7 On-Site Support & NOC: Expert assistance around the clock, 365 days a year
- 100% Green Energy
When is Housing the Right Choice?
- When you already own existing systems and your infrastructure must meet the strict security standards of GDPR compliance.
- When high-availability network infrastructure, power supply, and carrier connectivity are required.
- When an ISO-certified environment must be demonstrated for compliance.
- When you want to rely on 24/7 on-site support without having to organize it yourself.
- When flexible rack capacities (individual rack units, third rack, or full rack) are needed.
Technical Details
Traffic Commitment with 95/5 Billing Method
Billing is bandwidth-based. Using the “95/5 method,” measurement samples are recorded throughout the entire month, and the top 5% of peak values are eliminated before billing. This filters out short-term spikes and smooths the usage curve in the customer’s favor.
- The booked uplink (e.g., 1 Gbit/s) is available without throttling.
- Current traffic statistics (volume-based) can be viewed in ISAC at
cloud.isac.de. - Monthly billing is carried out retroactively.
Dimensions
The 19” racks measure 60 × 120 cm. There is ample space for cable routing; cable channels are also separated in third racks. At 47 U, the racks are comparatively tall – a step ladder is available on site for installation.
To make optimal use of the cooling concept, only 19” rack servers may be installed. Unused rack units should be covered with blanking panels to prevent any loss of cooling efficiency.
Connectivity
For individual rack units, InterNetX provides a shared switch with 1 Gbit/s (copper). Booking a redundant uplink is recommended.
For lockable racks, a switch can be optionally ordered or you can use your own hardware. The following options are available:
- Redundant (requires LACP and, when using two switches, stacking support)
- At 1 Gbit/s: Fiber optic (multimode as standard) or copper (RJ45 connector)
- At 10 Gbit/s: Fiber optic only (multimode as standard, LC connector; SC in exceptional cases)
- Higher uplinks: Available upon request
To migrate an existing dedicated carrier connection or order access to a hyperscaler (Cloud Connect), please contact our sales team at vertrieb@internetx-housing.com.
Power Supply
Shared Rack (individual rack units)
- IEC C14 power strip available
- With appropriate cabling, the A/B feed can also be used (recommended)
Full Racks or Third Racks
- Red CEE 16A three-phase power connectors (3 phases) pre-installed
- Switched and metered PDUs (Power Distribution Units) optionally bookable; customer-owned PDUs possible upon arrangement
- If no PDUs are used, C14 power strips are installed: six in a full rack, two in a third rack (one per phase)
Note: Work beneath the raised floor may only be carried out by InterNetX specialists and must be requested in advance via a support ticket.
Cooling
In the data center, the racks are cooled using efficient cold aisle containment. Compared to conventional solutions, this offers the following advantages:
- Server power consumption is reduced by approx. 30%.
- Cooling capacity is also designed for resource-intensive applications.
Data Center Access
Access regulations depend on the booked rack scope:
Customers with a Dedicated Full Rack
- First visit: During the first appointment, biometric registration (fingerprint) and a site-specific safety briefing (including a ban on drinks on the raised floor, light management, etc.) take place. First-time visits should be announced in advance via a ticket.
- Regular access: Once registered, you have free 24/7 access to your own rack – without advance notice or a ticket.
- Freight elevator exception: If the freight elevator is required for a hardware delivery, advance notice of at least 24 working hours is required.
Customers with Individual Rack Units (Shared Rack)
- Biometric registration does not apply.
- Every visit must be announced at least 24 hours in advance via a support ticket (including full name, email address, phone number, preferred date/time, and purpose of the visit).
- A valid government-issued photo ID (national ID card or driver’s license) must be presented at every visit.
- Throughout the entire stay in the data center, visitors are accompanied by InterNetX staff. Without timely advance notice, accompaniment cannot be guaranteed and access may be denied.
Goods Receipt, Storage & Logistics
Delivery Address (Goods Receipt & NOC)
InterNetX GmbH
3rd Floor / NOC (Office Floor & Goods Receipt)
Elisabeth-Selbert-Str. 7
80939 Munich, Germany
- Announcing deliveries: Hardware deliveries must be announced in advance via a support ticket so they can be clearly assigned (at least 24 working hours in advance if the freight elevator is needed).
- Goods receipt & packaging: The on-site team receives customer hardware and stores it until installation. Cardboard boxes and packaging materials are disposed of directly.
- Fire protection in the rack: No additional items (tools, spare parts, cardboard boxes, foils, etc.) may be stored inside the rack itself, as they pose a fire load. Tools and rack rails must be brought along by the customer; spare parts can be stored on site upon arrangement.
- Return shipments & move-out (Logistics): Small parts can be packed and shipped directly by the on-site team. Larger shipments (e.g., when a housing customer moves out) are handled by Logistics during regular business hours. For this purpose, please provide a hardware description (type, quantity, reference), preferred pickup/delivery date, pickup and delivery addresses with contact persons, as well as any special shipping instructions (packaging, weight, number of packages, freight forwarder if applicable).
Booking Remote Hands & Maintenance
To ensure your requests are processed quickly without follow-up questions, please include the following information when creating a ticket:
- For Remote Hands & Incidents (e.g., reboots, LED checks, cable checks):
- Hostname, slot, port, and exact location (rack, rack unit)
- For SFP issues: exact SFP model
- Description of the fault or requested action and preferred time window
- Contact person (phone and email) for real-time coordination
- For Maintenance & Deployment (new installation, hardware upgrades, decommissioning/data destruction):
- Detailed description of the work to be carried out
- Hardware details (type, manufacturer, model, serial number)
- Exact location (room, rack, U position)
- Scheduled date and time
Additional Information
- Provisioning: Rack space is ready within a few business days; optional services such as dedicated carrier connections are provided upon arrangement.
- On-site equipment: A monitor cart and a step ladder are available for general use. For preparatory work, the “Unpack & Deploy Room” including Wi-Fi can be used free of charge.
- Maintenance announcements: Planned maintenance is published via
status.internetx.com(notifications can be subscribed to via email, SMS, or push message). - Management & invoices: Further details on servers/racks as well as invoice overviews can be found in the ISAC customer portal at
cloud.isac.de.
Contact Details & Availability
Technical Support, 24/7 NOC & Hands-On Services
- Support ticket: Via
cloud.isac.de(under “Help” in the menu bar) - 24/7 NOC & Support Hotline (365 days):
+49 941 59559-480 - Regular business hours (Munich Data Center Team): Monday – Friday, 08:30 – 17:00
- Urgent / critical incidents: Please open a ticket with the appropriate priority and additionally notify the NOC directly by phone at
+49 941 59559-480.
Consultation & Sales
- Email:
vertrieb@internetx-housing.com - Availability: Monday – Friday, 08:30 – 17:00
Note: Processing requests outside the agreed service level may be subject to additional charges.
Was this article helpful?
Thanks for the feedback.